Research Protocol
 

By Dr. Giovan Giuseppe Mattera , Prof. Emilio Vanoli , Dr. Francesca M Loi , Dr. Valentina Martinez , Dr. Franco Borsini
Corresponding Author Dr. Giovan Giuseppe Mattera
Dept. Pharmacology- R&D Sigma Tau, SpA, Via Pontina, Km 30.400 - Italy 00040
Submitting Author Dr. Giovan Giuseppe Mattera
Other Authors Prof. Emilio Vanoli
University di Pavia, Cardiology Dept, - Italy

Dr. Francesca M Loi
R&D- Sigma Tau, SpA, - Italy

Dr. Valentina Martinez
R&D-Sigma Tau.it, - Italy

Dr. Franco Borsini
R&D- Sigma Tau, SpA, - Italy

PHARMACOLOGY

QT/QTc, Safety pharmacology, QT liability, Dog, Telemetry, QTc analysis

Mattera G, Vanoli E, Loi FM, Martinez V, Borsini F. Detecting Drug-induced QT Interval Prolongation in Healthy Dogs: A Practical Approach. WebmedCentral PHARMACOLOGY 2012;3(8):WMC003615
doi: 10.9754/journal.wmc.2012.003615

This is an open-access article distributed under the terms of the Creative Commons Attribution License(CC-BY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
No
Submitted on: 03 Aug 2012 12:51:54 PM GMT
Published on: 03 Aug 2012 07:09:48 PM GMT

Introduction


Safety assessment of new chemical entities (NCE) is essential to provide Drug Company‘s Management with data to inform decision making to discontinue development of unsafe drugs early or to convince the Regulatory Authority that an efficacious NCE is also safe. These considerations imply that a modern company must to create an efficient Safety Pharmacology Department equipped with up to date instruments and validated methodologies. In that process, particular attention must be paid to the risk assessment of drug-induced QT interval prolongation, as biomarker of Torsade de Point (TdP), a potentially lethal arrhythmia. In fact, a specific guideline has been dedicated to this particular aspect (ICH S7B, 2005).

So far, some critical challenges to pre-clinical Cardiovascular Safety Pharmacology (CSF)Specialists (Guth et al, 2009) exist:
1. The choice of a predictive test system
2. The accuracy in ECG traces recording
3. A reliable waveform measurement and ECG analysis system  
4. The correct assessing of QT interval prolongation. Furthermore, there is little documentation about standardization and validation of currently commercially-available and employed hardware/software (HR/SW) systems to ECG analysis methods in pre-clinical studies (Chui and Vargas, 2009).

Actually, animal models are anymore an issue, due to the wide consensus about dogs and monkeys as suitable animal models (Batey et al., 2002; Holzgrefe et al., 2006). In fact, together with the use of chronically telemetry-instrumentation, their use are recommended by the regulatory guidelines (ICH S7A, 2000; S7B, 2005). In such models, drug-related hemodynamic and ECG changes can be evaluated in the same animal and in real time for long period, without restrain or anaesthesia interference. Because of its advantages, and with the amelioration of implant techniques, telemeter-implanted animals are now the best alternative to “traditional” animal ECGs recording techniques also in term of traces quality. In fact, the first need for a successful electrocardiographic study is availability of high quality ECG traces that allow a precise evaluation of the waveform segments. Of course, the availability of high volume of ECG data due to the digital data recording improvement, pointed out the necessity for investigators of an accurate, efficacious and quick system for ECG analysis. The implementation of potent algorithms for measurement of ECG wave’s segments in commercial SW, releases the company to the necessity of development of “home-made” ECG analysis SW. This availability, together with the impressive increment of personal computers performances, allows investigators to manage huge amount of data in a relatively simple way. As a result, automated ECG analysis is becoming a mainstream method to optimize hemodynamic and ECG data analysis. Commercially available applications offer different approaches to automated ECG analysis for quantifying cardiac intervals, i.e. attribute-based or pattern-recognition-based platforms, or a combination. Recently, a report comparing these approaches concluded that the pattern-recognition-based platform was the most suitable to adapt to ECG morphology changes observed in long term ECG study (Chui and Vargas, 2009).

Despite dramatic improvement of data analysis power, the issue of a method to assess QT interval prolongation, however, is not yet resolved and there is no general consensus about the best method to use. Numerous factors are implicated in duration and variability of ventricular repolarization. This has obvious consequences on the understanding of pharmacologically induced modifications. The QT interval duration in fact, is strongly dependent on heart rate (HR) and thus, directly varies with changes in the RR interval. Noteworthy is the fact that QT interval rate-adaptation is not precisely regulated on a beat-to-beat basis. In fact, it is strongly influenced by the preceding HR history, a well-described phenomenon referred as “QT hysteresis” (Pueyo et al, 2003). Moreover, QT interval duration is also partly conditioned by autonomic activity oscillations (Ahnve & Vallin, 1982), electrolyte disorders (Jackman et al. 1988), exercise, changes in cardiac after load, stressful situations, etc.

For these reasons, linear regression based-formulae had been proposed to correct the QT interval (QTc) for HR changes since 1920 (Bazett, 1920; Fridericia, 1920). However, despite the general consensus in clinical practice to use these, and others, formulae generally they provide satisfactory QTc only within a narrow range of heart rates (60/80 bpm). In the animal models like dog, however, usually a wider and less stable RR intervals range than in humans is present (<60 up to >150 bpm). As consequence, QTc formulae like Bazett or Fridericia, or other single-coefficient models, fail to properly describe the QT/RR relationship in the dog. Consequently, this unresolved imprecision in QT rate-correction methodology has fostered newer mathematical approaches. A number of different ECG analysis approaches based on individual correction, proposed by many authors (Batey et al., 2002; Fossa et al., 2002; Matsunaga et al., 1998; Holzgrefe et al., 2006), are currently available. Compared to standard formula-based approaches, it is now clear that individually tailored QTc offers improved, but still imperfect solutions (Batchvarov et al., 2002; Malik, et al., 2002) and often, they are too complex to apply in routine testing, specifically for the heavy data processing and analysis, and/or sometime, the need of development of specific computer applications. One of the alternative methods recently under consideration is dynamic beat-to-beat QT/RR relationship (QTbtb) analysis (Fossa et al, 2002; Batey and Doe, 2002). Using all sequentially collected beats from ECG, this method of analysis allows to compare QT intervals to individual cardiac cycles, from all normal autonomic states, at similar RR intervals, thereby eliminating potential sources of error from the use of correction functions. Recently, the efficacy of this method to differentiate changes of QT interval duration due to heart rate or autonomic state, from impaired repolarization, it has been reported (Fossa et al, 2005). But in the lack of a “golden standard”, and in the absence of consensus about the best QT correction method(s), QT interval measurement and analysis method choice play the role of key issue in daily CSF Specialist work. At the actual State-of-Art, in vitro data plus the combination of different in vivo QT analysis methodologies could give un-ambiguous answer to the Company Management if a NCE can be developable and/or fulfil the safety standard required by Regulatory Authority.

Aims and Objectives


Aim of this report is to describe our experience about the implementation of a modern and efficient CSF laboratory taking into account all the above reported considerations, with particular attention to develop, standardize and validate a relatively simple, powerful and user friendly practical data analysis procedure. Such a procedure utilizes commercially available SW with built in a combination of QT-RR relationship, on a Beat-to-Beat basis, and individual- and classical QT rate-correction based analysis. The hardware/software set up and analysis method (HW/SW System) were validated trough the comparison of the effects on QT interval induced by 2 well-known QT interval prolonging drugs of two different therapeutical classes: the antiarrhythmic sotalol (Sot) and the H1 antagonist astemizole (Ast) (Hashimoto et al, 1998; Snook et al, 1998). Finally, the system was tested “on the road” performing a GLP study on a NCE, ST 1326, a Sigma-Tau, S.p.A. drug candidate.

Materials and Methods


All aspects of the study concerning animal care were performed in compliance with the Guide for the Care and Use of Laboratory Animals published by the National Institutes of Health (NIH Publication 85-23, revised 1985) and the Italian regulatory system (D.L. 116, Art. 6 of 27 Jan 1992) under the control of Sigma-Tau veterinarians. All experiments were conducted in compliance with GLP rules and internal SOPs using GLP validated computer system and procedures.

Animals and housing conditions: Eleven male Beagle dogs bred for scientific research (11 to 13 kg body weight upon arrival, Harlan, Natisone, UD, Italy) were used. The animal room had the following environmental conditions: temperature: 18 ± 2 °C, relative humidity: 55 ± 10%, about 15-20 filtered air changes/hour and a 12-hour circadian cycle of artificial light (7:00 am – 7:00 pm). Animal room cleaning from 8:00 to 10:00 am. The animals were fed ( Tekland 2021 Dog Maintenance; Harlan, Natisone, UD Italy) once a day at 09:00 am. Drinking water was given ad libitum through an automatic system.

Surgical Preparation: Overnight-fasted dogs were pre-anesthetized with intramuscular injection of Zoletil 100®(tiletamine hydrochloride and zolazepam hydrochloride; Virbac – Carros, France).  After tracheal intubation, the surgical anesthesia level was obtained and maintained by ventilation with isoflurane (1.5-2.5%) in an oxygen-nitrous oxide mixture. Body temperature was maintained at 37.5 ± 1 °C. A left thoracotomy was performed in the 4th/5th intercostal space. Each dog was instrumented with radiotelemetric devices (Mod. TL11M2-D70-PCTP, DSI, St Paul, MN). Briefly: dogs underwent to left toracotomy to expose aortic arch and heart. Sensor 1 was inserted into aorta to monitor systemic blood pressure, sensor 3 was inserted into left ventricle through  (radiotelemetry pressure data are not a part of current study and are not reported herein). ECG lead placement was epicardial, thus the two cables of sensor 2 (ECG sensor) were secured, the positive ECG electrode was sutured directly to the left ventricular epicardium near the ventricular apex, while the negative lead was secured to the mediastinal reflection near the base of the right atrial appendance (LEAD II like configuration).

Finally, the telemetric transducer body was fastened into subcutaneous task and secured.

In four out of eleven dogs, a titanium vascular access port (Harvard Apparatus, Inc., MA, USA) was also implanted for continuous iv infusion. After all surgical procedures, the antibiotic Spectrum® (ceftazidima 1 g per day, Sigma Tau, Pomezia, Italy) and Contramal® (tramadol HCl 50 mg bis die, Formenti, Mi, Italy) were administered for four days. The animals were allowed to recover for at least two weeks before experimental procedures.

Data Acquisition Laboratory: Hardware and Software: The Telemetric Acquisition Laboratory consists of two areas, the first for animal housing and signals detection (Animal Room) and the second for data monitoring and recording computer system (Data Room). Dogs, throughout the study period, were housed individually in stainless-steel cages (l 110 x w 225 x h 300 cm) each equipped with two receivers (RMC-1, DSI, St Paul, MN, USA) to cover the entire cage area. Each receiver, as well as the Ambient Pressure Reference module (APR-1, DSI, St Paul, MN, USA), positioned in the Animal Room is wired with the Data Exchange Matrix (DEM, DSI, St Paul, MN, USA) connected to the HW/SW data acquisition system: HP Workstation xw4100 (Hewlett-Packard) plus Dataquest A.R.T. V 4.1 Gold, accessorized with Diagnostics, Security Manager and GLP Auditor modules (DSI, St Paul, MN, USA), positioned in the adjacent Data Room. All digital signals were stored on hard disks configured as RAID 1 (Mirroring) to improve data security. The system was GLP validated.

Telemetric ECG and hemodynamic  monitoring: During the study ECG sampling rate was 1 KHz. The high sampling rate for the ECG was specifically important as it implies a < 2 ms interval resolution, minimizing the recording error. All data are filtered through a 1 – 100 Hz band pass filter which is coded into transmitters, and is not modifiable by the end user.

All experimental sessions started at 11:00 am of first day and ended after 24-26 hours of continued data acquisition. To obtain discrete sampling periods, signals were sampled and recorded continuously for 5 min every 1 min, thus 10 steps per hour were collected, each of them consisted of approximately 300-500 consecutive cardiac cycles.

System and method validation
Experimental protocol: The day before starting the first experimental session, dogs underwent a 24 h parameters recording to obtain individual reference values (pre-study Session). The data from each dog were averaged to obtain the mean values over 24 h in free-moving, untreated conditions. Further, the presence of circadian rhythmicity was simply investigated by dividing the acquired data in 2 time period defined as: Day (11:00 am to 7:00 pm), and Night (7:00 pm to 7:00 am) and the values of each period averaged to obtain the diurnal and nocturnal mean values.

Drugs dose levels and treatment schedule: Placebo (Gelatin capsules), sotalol (3, 10, and 30 mg/kg) and astemizole (1, 3 and 10 mg/kg) were orally administered. Sotalol and astemizole were chosen on the basis of their documented capability of inducing QT interval prolongation and/or TdP in animals and humans (Hashimoto et al, 1998; Snook et al, 1998). Then each dog was randomly assigned to placebo or test items treatment following a randomized 7x7 Latin Square experimental design. A washout period of at least 1 week between the seven experimental sessions was applied. On the day of dosing, telemetric signals from each animal were monitored continuously for at least 2 h pre-dose (11:00 am – 1:00 pm; BASAL), and up to 20 h after drugs administration (DRUG ADMINISTRATION).

Data  analyses: Raw data were analysed on a separate data analysis HW/SW system: HP Workstation xw4600 (Hewlett-Packard) with hard disks configured as RAID 1 (Mirroring), and Dataquest A.R.T. Analysis Only V 4.1 with File Format Utility module (DSI, St Paul, MN, USA) plus ECG AUTO2 V2.4.0.29 with Files Converter Utility v2.3.0.3 (EMKA Tech., Paris, Fr).

Study’s  parameters: Digital ECG raw data were converted in a ECG AUTO2 readable file format and HR, cardiac intervals (PR, RR, QRS and QT), QT-RR relationship and rate-corrected QT intervals, by the means of 3 different formulae: Van de Water, Matsunaga and individually rate-corrected by regression (QTcReg) formula (2), were calculated.

QT/RR relationship and QTcReg formula: Individual QTbtb was studied for each dog, in both pre-study and in pre- and post-treatment condition, applying the “2-parameters non-linear fitting” formula of Carmeliet [1]

a*(1-esp(f(RR))                [1]

where a = measured QT, and f = coef. f of regression (Fig. 2). A fitting r2 value >0.600 was considered satisfactory. The QT interval values, obtained for each dog, at three RR reference (RRref) intervals: 600 (HR=100 bpm), 800 (HR=75 bpm) and 1000 ms (HR=60 bpm), were reported in a table (i.e. Table 2). The QT value at RRref of 1000 ms, obtained for each dog from 24 h pre-study Session data analysis, was also assumed as QTref value to build the individual QTcReg formula [2].

QTcReg = QT + QTref - (QT * 1-f * RR)           [2]

where QTref is QT value at reference RR interval, and f = coef. f of regression.

ECG analysis procedures: Briefly: ECG traces quality was inspected on monitor screen by a skilled operator. ECG AUTO2 processes data using shape-recognition techniques and a library of model waveforms as reference. The reference library is built, enriched and edited by the operator. Library of representative ECG complex waveforms, derived by all recordings, is iteratively built for each dog. When the recognition performances appears satisfactory (Fig. 1), the analytical process progresses in four

consecutive steps:
Step 1: Definition of the list of parameters to measure (Tuning analysis) and identification of the ECG segments (i.e. daytime, pre-dosing, dosing, etc.) to be processed (Protocol writing).
Step 2: The pre-study Session QTbtb ECG analysis and build of the individual QTcReg formula
Step 3: Treatment Sessions ECG analysis
Step 4: Review and save of the results: the accepted analysis results were saved on files, printed and archived.

Statistical analysis: The individual data are averaged and mean ± standard deviation reported. Statistical analysis of QTbtb was performed by paired student t test or one way ANOVA followed by Dunnett’s multiple comparison test. Statistical analysis of QTc time course was performed by two way repeated measure ANOVA followed by Dunnett’s multiple comparison test. A value of p < 0.05 was considered as statistically significant.

“On the road” validation

Finally, to test the system and methods under operative conditions, a GLP CSF study was performed on a Sigma Tau NCE under evaluation, ST1326.

Animals preparation, dose levels and treatment schedule: A group of 4 dogs was prepared as above described. Route, duration and doses of test item were chosen on the basis of putative route, doses and duration of administration in humans. ST1326 (1, 3, and 6 mg/kg/24 h) or vehicle (physiologic saline) was administered to each dog on the basis of individual body weight as continuous 24 h i.v. infusion by the means of a portable mini-pump (Dakmed II ) accommodated in a lateral pocket of a dog jacket. Each dog was randomly assigned to vehicle or ST1326 in a crossover sequence, according to 4 x 4 Latin square design, a washout period of at least two weeks between each of the four experimental sessions were respected.

In a second group of 4 animals, randomly chosen in the group for the validation study, Placebo (gelatin capsules) or Sotalol (3, 10 and 30 mg/kg) as positive control, was administered orally following a similar treatment schedules as aforementioned.

Parameters acquisition and Data analysis: The day before starting the first experimental session, dogs underwent to a 24 h parameter recording to obtain individual reference values (pre-study Session). On the day of dosing, telemetric signals from each animal were monitored continuously for at least 2 h pre-dose (11:00 am – 1:00 pm; BASAL), and up to 26 h after drugs administration (DRUG ADMINISTRATION). To monitor, recording and analyze the study parameters the above described procedures were applied.

Results


System and method validation:
Twenty-four-h parameters in free-moving, untreated animals (pre-study Session).

No arrhythmias or electrocardiographic abnormalities were observed in any of the recordings, except for the respiratory sinus arrhythmia that is a normal finding in beagles.

Animals showed a nocturnal statistically significant HR reduction, and increase in RR and QT interval duration with respect to day time. Whereas, PQ and QRS did not change (Table 1). Moreover, circadian variations of ventricular depolarization duration were further confirmed by QTbtb and QTc analysis (Fig. 2, 3). Fig. 2 represents also an example of the typical distribution of the QT-RR bins, showing the wide range of RR intervals obtained from 24 h ECG of a given dog. QT/RR  showed a non linear relationship, along with a hyperbolic curve due to a flattening of the relation at the longer RR interval (lower HR). It is worth noting that the QT/RR plot exhibits two distinct regions separated by a marked inflexion at an RR interval of approximately 600 ms (Fig. 2); a wide range of QT interval values was also found for the same RR interval. Moreover, although a similar slope, the comparison of QT/RR relationship during Day time and Night demonstrated that, during the night, QT interval duration was systematically longer at any of the RR intervals (Fig. 2). In fact, QT interval duration showed an average Day to Night increase of 5-10 ms at each RRref (Table 3). Thus, QTbtb analysis clearly points out the presence of a rate independent circadian rhythm of cardiac depolarization. Further, QTc analysis confirmed on one side, that QT interval was longer in the Night than in the Day; on the other, the flat QTcVdW curve confirming that it is the less effective formula to correct QT for the wide range of RR intervals present in dogs (Fig. 3) with respect QTcM and QTcReg.

Effect of sotalol: Sotalol (3, 10 and 30 mg kg-1, os), as compared to placebo administration, induced a modest, non dose dependent, but consistent and statistically significant, reduction of HR (p<0.001). Moreover, sotalol administration without affecting QRS interval, increased consistently and dose-dependently RR, PQ and QT intervals duration (Fig. 4). The sotalol-induced increase of uncorrected QT duration (Fig. 4), confirmed by both QTbtb analysis (Table 3, Fig 5) and by rate-corrected QT interval analysis (p<0.01; Fig. 6), which is clearly not rate-related.

Effect of astemizole: Astemizole administration as compared to placebo, induced a relevant and statistically significant increase of HR (p<0.001; Fig. 8) and thus, RR interval duration reduction, only at the higher dose. Whereas, PQ and QRS interval durations unchanged at any dose (Fig. 18). Uncorrect QT interval duration was slightly, but statistically significant increased after administration of 3 and 10 mg/kg (Fig. 8). The not rate-related astemizole induced QT interval prolongation was confirmed by QTbtb analysis (Table 4), and by rate-corrected QT interval analysis with all three correction formulas used (p<0.01; Fig. 9).

“On the road” validation

All parameters recorded during pre-study Sessions were similar in both animal groups (for QT interval see Table 5). Thus, they were averaged and analyzed together. All daily parameter variations previously observed, i.e. nocturnal increase in RR, and QT/QTc, reduction of HR, etc. were substantially confirmed in this second study (data not showed). Remarkably, there was the intra-individual consistency on QT interval duration over time (see Table 2 vs Table 5).

Placebo administration or vehicle infusion did not induce physiologically relevant differences in ECG parameters in the two groups. Thus all control animals were considered as a unique Control Group (n=8).

On the contrary, sotalol administration, with respect to Control Group, and consistently with previous validation study, without affecting QRS interval, dose-dependently increased RR, PQ and QT intervals duration. The last finding was confirmed by QTbtb analysis (Table 6), and by rate-corrected QT interval analysis with all three correction formulas used.

Effect of  ST1326 in healthy, free-moving dogs

During 24 h infusion of ST1326, HR, RR, PQ and QRS were not affected by treatment in a statistically significant manner at any of the tested doses (data not showed), as well as QT interval. In fact, both QTbtb analysis, as well as the 3 used QT correction formulae, failed to show any significant difference with respect to Control animals (Table 7, Fig. 9 ).

Discussion


Actually there is not yet agreement about the best method(s) to assess unequivocally drug-induced QT prolongation. In fact, this matter remains object of vivid debate between SF specialist and Regulatory Authority. But the need of simple, efficacious and practical approach to the matter remains the primary objective of the SF Specialist for his daily work. The present report documents our experience on the possibility, using a commercially available HW/SW system,
1. to equip an efficient CSF Lab  
2. to develop and validate a relatively simple protocol to efficiently test NCEs safety to fulfill the Authority recommendations.     

The efficacy and sensitivity of implemented HW/SW System are testified from experimental data obtained during the validation study. In fact, it was sufficiently sensible to detect the very small circadian variation of QT interval duration (5-10 ms) and to demonstrate unambiguously its rate-independency. Moreover, comparing the circadian pattern of QTc derived by the three used correction formulae in reference to QTbtb analysis, we found, as also previously shown in humans (Smetana et al., 2003), that the extent of circadian pattern of QTc is substantially influenced by the correction formula used.

The efficiency of the System to detect drug-induced QT duration prolongation was challenged with two well-known QT interval lengthening agents of two different therapeutic class: sotalol and astemizole.

Administration of both sotalol and astemizole dose-dependently increased QT interval duration as immediately evident from QTbtb analysis (RR800= up to 27 and 10 ms, respectively). The QT interval was already prolonged dose-dependently at 1 hour and up to 18 hours. The results, taken as a whole, fully confirm previous findings  with such drugs (Batchvarov et al., 2002; Batey et al., 2002; Thomsen et al., 2004, Hashimoto et al. 1998; Snook et al. 1998).

QT correction methods have long been a topic of much debate. Awareness that classical methods, such Bazett’s or Fridericia’s, fail to adequately correct the QT interval on large RR interval spectra, have led to the application of a number of linear or nonlinear fitting equations, which force a mathematical function to the QT/RR relationship with varying degrees of success. Matsunaga et al (1998) also studied fourteen different mathematical formulae to fit RR-QT data on Beat-to-Beat base demonstrating that Carmeliet’s formula provides one of the best fit. Accordingly, in our hands, by the means of our experimental setup, to apply the ECGAuto built in Carmeliet’s fitting formula to QTbtb, resulted powerful and simple to apply. We confirmed that QT/RR relationship is curvilinear (Fossa et al, 2002;  Matsunaga et al, 1998) and that the method is sufficiently sensible to demonstrate circadian or drug-induced rate independency of QT interval prolongation. Overall, telemetric long term ECG recording enables a relatively simple physiological description of the daily relationship between RR and QT intervals of undisturbed regularly housed dogs. Moreover, it adequately describes the rate independence of drug-induced changes in repolarization without recourse to a more complicate mathematical modeling or self made SW. Finally, our results are in complete agreement with the data binning technique of Beat-to-Beat analysis described by Batey and collegues (2002), but with the advantage that the MSExel driven data binning was not necessary. A common criticism to this type of analysis is that sorting the QT data by RR interval removes the time-course of a drug’s effect. However, our data demonstrated that the analytical approach here used, through the simple division of the 24h records in different time periods, i.e light and dark, permits to easily discriminate the circadian HR independency of QT prolongation. Thus, QT/RR relationship, in the absence of drug, can be used as a “calibration” to determine the expected QT value for a given RR at different day-time. Moreover, the system permits to integrate the findings with the contemporary application of individual or population based rate correction formulae to fully exploit the time course of the phenomenon.

The advantage of chronically telemeter-implanted dogs as test system is supported, today, by a large bulk of evidence (Batey et al., 2002; Fossa et al., 2005; Holzgrefe et al., 2006)  and it is also fully confirmed by our results. In fact, by employing this technology, a small cohort of animals was sufficient to provide meaningfull information using cross-over study following a Latin Square design. Although the number of data points obtained from a 24 h recording in this study is very large, results are manageable by a standard commercially available HW/SW combination. Further, the built in QTbtb analysis as well as some formulae for QTc interval analysis, permits to combine the classical population-based QT evaluation methods to the new potent individual-based methods emerging in the international literature (Malik et al., 2002; Fossa et al., 2005; Holzgrefe et al., 2006) without sensible time cost increases.

Effectiveness of different corrections: When safety studies are planned, it is important, to avoid over- or under-estimation of the real effect on QT exerted by NCE. Time course plot of daily trend of RR and QT interval showed a variation of parameters along the day. Circadian rate independency of QT interval, as well as drug-induced QT prolongation, was properly detected by applying the Regression and Matsunaga rate-correction equations. On the other hand,  the Van de Water equation gave unclear results and did not adequately represent the circadian or drug induced, QT/RR relation changes. Overall the impression was that the Van de Water equation over-corrects at high HR and under-corrects at low HR. Consequently, it is not useful and thus anymore used.

Conclusion


We have described an experimental set-up, combining dog as animal model, telemetric technology, and validated HW/SW System that permits contemporary QTbtb and QT interval rate-correction analytical approaches. This set-up is easily usable, allows the generation of huge databases of ECG complexes and the correct identification of drug-induced QT changes. The results strongly support the use of uncorrected QT at comparable RR intervals, as they are provided by long term recording, to properly generate unambiguous information on ventricular repolarization using QTc as complementary analysis. Moreover, for pre-development safety assessment, it is sufficient to apply, for its immediacy and efficacy, the Matsunaga QTc formula. Whereas it is advisable for a more complete analysis to add QTcreg formula, that requires more time to implement,  only for GLP Regulatory studies.

We hope that our experience with this set-up should help colleagues during  implementation of own Cardiovascular Safety Pharmacology Labs, and that the described protocol might be taken into consideration as one of the possible standard procedure in assessing the cardiovascular safety of new compounds under development.

Acknowledgment


We gratefully acknowledge the expert technical assistance of Mirna Botarelli to perform the experiments, and that of  Daria Di Giulio in the preparation of the manuscript.

References


1. Ahnve, S.,  Vallin, H. (1982). Influence of heart rate and inhibition of autonomic tone on the QT interval. Circulation, 65, 435-9.
2. Batchvarov, N.V.,Ghuran, A., Smetana, P., Hnatkova, K., Harries, M., Dilaveris, P., et al. (2002). QT-RR relationship in healthy subjects exhibits substantial itersubject variability and high intrasubject stability. American Journal of Physiology. Heart and Circulation Physiology, 282, H2356-H2363.
3. Batey, A.J., & Doe, C.P. (2002). A method for QT correction based on beat-to-beat analysis of the QT/RR interval relationship in conscious telemetered beagle dogs. Journal Pharmacological and  Toxicological Methods, 48, 11-19.
4. Bazett, H.C. (1920) An analysis of the time-relations of electrocardiograms. Heart, 7, 353-370.
5. Chui R.W., Vargas H.M. (2009). A Comparison of three software platforms for automated ECG analysis. J of Pharmacol. Toxicol. Meth. 60, 28-38.
6. Fossa, A.A., De Pasquale, M.J., Raunig, D.L., Avery, M.J., Leishman, D.J. (2002). The relationship of clinical QT prolongation to outcome in the conscious dog using a beat-to-beat QT-RR interval assessment. Journal Pharmacological Experimental Therapeutics, 302, 828-33.
7. Fossa, A.A., Wisialowski, T., Magnano, a., Wolfgang,E., Winslow, R., Gorczyca, W., Crimin, K., Raunig, D.L., (2005). Dynamic Beat-to-Beat modelling of the QT-RR interval relationship: Analysis of QT prolongation during alterations of autonomic state versus human Ether a go-go-related gene inhibition. Journal Pharmacological Experimental Therapeutics, 312, 1-11.
8. Fredericia, L.S. (1920). Die Systolendauer im Elektrokardiogramm bei normalen Menschen und bei Herzkranken. Acta Medica Scandinava, 53, 469-486.
9. Guth B.D., Bass A.S., Briscoe R., Chivers S., Markert M., Siegel P.K.S., Valentin J.P. (2009). Comparison of electrocardiographic analysis for risk of QT interval prolongation using safety pharcology and toxicology studies. J Pharmacol. Toxicol Meth. 60, 107-116.
10. Hashimoto H, Nishimoto M, Ohmura T, Watanabe S, Ikeda Y, Nakamura R, Umemura K, Nakashima M. Effects of astemizole on ventricular activation, effective refractory periods, RT interval, and programmed stimulation-induced ventricular arrhythmias in dog heart with myocardial infarction. J Cardiovasc. Phaermacol 1998; 31:286-291.
11. Holzgrefe, H.H, Cavero, I., Gleason, C.R., Warner, W.A., Buchanan, L.V., Gill, M.W., Burkett, D.E., Durham, S.K. (2006). Novel probabilistic method for precisely correcting the QT interval for heart rate in telemetered dogs and cynomolgus monkeys.  Journal Pharmacological and  Toxicological Methods, 55, 159-175.
12. ICH harmonised tripartite guideline, S7A. (2000). Safety pharmacology studies for human pharmaceuticals.
13. ICH harmonised tripartite guideline, S7B. (2005). The non-clinical evaluation of the potential for delayed ventricularrepolarization (QT interval prolongation) by human pharmaceuticals.
14. Ishizaki, T., Hirayama, H., Tawara, K., Nakaya, H., Sato, M., & Sato, K. (1980). Pharmacokinetics and pharmacodynamics in young normal and elderly hypertensive subjects: a study using sotalol as a model drug. Journal of Pharmacology and Experimental Therapeutics, 212, 173-181.
15. Jackman, W.M., Friday, K.J., Anderson, J.L., Aliot, E.M., Clark, M., & Lazzara, R. (1988) The long QT syndromes: a critical review, new clinical observations and a unifying hypothesis. Progress in Cardiovascular Diseases, 31,115-172.
16. Malik, M. (2001). Problems of heart rate correction in assessment of drug-induced QT interval prolongation. Journal of cardiovascular electrophysiology, 12, 411-420.
17. Malik, M., Farbom, P., Batchvarov, V., Hnatkova, K., & Camm, A.J. (2002). Relation between QT and RR intervals is highly individual among healthy subjects: implication for heart rate correction of the QT interval. Heart, 87, 220-228.
18. Malik, M. (2004). Errors and misconceptions in ECG measurement used for the detection of drug-induced QT interval prolongation. Journal of Electrocardiology, 25-33.
19. Matsunaga, T., Mitsui, T., Harada, T., Inokuma, M., Murano, H., & Shibutani ,Y. (1998). QT corrected for heart rate and relation between QT and RR intervals in beagle dogs. Journal Pharmacological Experimental Therapeutics, 38, 201-209.
20. Nattel, S. (1999) Class III Drugs: Amiodarone, Bretylium, Ibutilide and Sotalol. in D. Zipes, & J. Jalife (Eds.), Cardiac Electrophysiology, From cell to Bedside. 3rd edition, Chapter 100, W.B. Saunders Company, Philadelphia.
21. Pueyo, E., Smetana, P., Laguna, P., & Malik, M. (2003). Estimation of the QT-RR hysteresis lag. Journal Electrocardiology, 36 Suppl, 187-190.
22. Sasaki, H., Shimizu, N., Suganami, H., & Yamamoto, K. (2005). QT PRODACT: inter-facility variability in electrocardiographic and hemodynamic parameters in conscious dogs and monkeys. Journal Pharmacological Science,  99, 513-22.
23. Smetana, P., Batchvarov, V.N., Hnatkova, K., Camm, A.J. & Malik, M. (2003). Circadian rhythm of QTc interval: impact of different heart rate correction models. Pacing and Clinical Electrophysiology, 26: 383 - 386.
24. Snook J, Boothman-Burrell D, Watkins J, Colin-Jones D. Torsades de Pointes ventricular tachycardia associated with astemizole overdose. Br J Clin Pract 1998; 42:257-259.
25. Thibault, B., & Nattel, S. (1999). Optimal management with Class I and Class III antiarrhythmic drugs should be done in the outpatient setting: protagonist. Journal Cardiovascular Electrophysiology, 10, 472-81.
26. Thomsen, M.B., Verduyn, S.C., Stengl, M., Beekman, J.D., de Pater, G., van Opstal, J., Volders, P.G., & Vos, M.A. (2004). Increased short-term variability of repolarization predicts d-sotalol-induced torsades de pointes in dogs. Circulation, 110, 2453-9.
27. USFDA (2003) Code of Federal Regulations, Title 21, part 11: Electronic Records, Electronic Signatures, Final Rule.
28. US FDA (2003) Code of federal Regulations, Title 21, Part 58: Good Laboratory Practice regulations.

Source(s) of Funding


The study was supported by Sigma Tau SpA

Competing Interests


The authors state no conflict of interest

Disclaimer


This article has been downloaded from WebmedCentral. With our unique author driven post publication peer review, contents posted on this web portal do not undergo any prepublication peer or editorial review. It is completely the responsibility of the authors to ensure not only scientific and ethical standards of the manuscript but also its grammatical accuracy. Authors must ensure that they obtain all the necessary permissions before submitting any information that requires obtaining a consent or approval from a third party. Authors should also ensure not to submit any information which they do not have the copyright of or of which they have transferred the copyrights to a third party.
Contents on WebmedCentral are purely for biomedical researchers and scientists. They are not meant to cater to the needs of an individual patient. The web portal or any content(s) therein is neither designed to support, nor replace, the relationship that exists between a patient/site visitor and his/her physician. Your use of the WebmedCentral site and its contents is entirely at your own risk. We do not take any responsibility for any harm that you may suffer or inflict on a third person by following the contents of this website.

Reviews
2 reviews posted so far

Detecting Drug-induced QT Interval Prolongation in Healthy Dogs: A Practical Approach--> Review
Posted by Mr. Peter Moran on 19 Dec 2014 07:49:51 PM GMT Reviewed by Interested Peers
This review will not be counted towards final review score for this article and for its inclusion into WebmedCentral Peer Reviewer articles because reviewer did not feel he/she had sufficient experience and knowledge to review the article.

Detecting Drug-induced QT Interval Prolongation in Healthy Dogs: A Practical Approach
Posted by Mr. Jackson Overton on 08 Dec 2014 07:33:23 PM GMT Reviewed by Interested Peers

Comments
0 comments posted so far

Please use this functionality to flag objectionable, inappropriate, inaccurate, and offensive content to WebmedCentral Team and the authors.

 

Author Comments
0 comments posted so far

 

What is article Popularity?

Article popularity is calculated by considering the scores: age of the article
Popularity = (P - 1) / (T + 2)^1.5
Where
P : points is the sum of individual scores, which includes article Views, Downloads, Reviews, Comments and their weightage

Scores   Weightage
Views Points X 1
Download Points X 2
Comment Points X 5
Review Points X 10
Points= sum(Views Points + Download Points + Comment Points + Review Points)
T : time since submission in hours.
P is subtracted by 1 to negate submitter's vote.
Age factor is (time since submission in hours plus two) to the power of 1.5.factor.

How Article Quality Works?

For each article Authors/Readers, Reviewers and WMC Editors can review/rate the articles. These ratings are used to determine Feedback Scores.

In most cases, article receive ratings in the range of 0 to 10. We calculate average of all the ratings and consider it as article quality.

Quality=Average(Authors/Readers Ratings + Reviewers Ratings + WMC Editor Ratings)