Research articles
 

By Dr. Ernst-ludwig Stein , Mrs. Dagmar Samsel , Dr. Ulrich Pachmann
Corresponding Author Dr. Ernst-ludwig Stein
SIMFO GmbH , Kurpromenade 2 - Germany 95448
Submitting Author Dr. Ernst-ludwig Stein
Other Authors Mrs. Dagmar Samsel
Labor Dr. U. Pachmann, - Germany 95448

Dr. Ulrich Pachmann
Labor Dr. U. Pachmann, Kurpromenade 2 - Germany 95448

HAEMATOLOGY

Factor VIII binding, Von Willebrand factor, Von Willebrand disease Type 2N, Relative stoichiometry, Relative affinity, Lineweaver-Burk

Stein E, Samsel D, Pachmann U. Relative Stoichiometry and Affinity for Describing Von Willebrand Factor Binding of Coagulation Factor VIII. WebmedCentral HAEMATOLOGY 2013;4(1):WMC003949
doi: 10.9754/journal.wmc.2013.003949

This is an open-access article distributed under the terms of the Creative Commons Attribution License(CC-BY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
No
Submitted on: 24 Jan 2013 05:49:57 PM GMT
Published on: 25 Jan 2013 08:56:34 AM GMT

Introduction


The von Willebrand Factor (vWF) is the biggest multimeric protein in the body and plays an important role in hemostasis. Its main functions are to bind to collagen, to platelet GPIb and to coagulation factor VIII (FVIII). Von Willebrand Disease (vWD) is the most common bleeding disorder in the Caucasian population. If, as a qualitative defect, a variant vWF protects FVIII less than normal, not only the adhesion but also the formation of the clot is affected. This type of diseases is called vWD type 2Normandie (2N) and it cannot be identified by an aberrant multimeric pattern. Using  the published home made [1-7] ELISA assays on the vWD Type 2N as well as one commercially available assay [8-9], it is not possible to determine the stoichiometry or the affinity of the interaction, which would make it possible to classify and to correlate the variant regions of the vWF-molecule with functional features. Furthermore, it is complicated to perform the home-made assays, because two ELISA plates have to be processed in parallel. To replace the ill-defined term “binding capacity” by terms of classical biochemical meaning, namely the number of binding sites and the affinity of the binding, a simple method has therefore been developed combining the advantages of both techniques, namely biochemical clarity of the results and technical straightforwardness to determine the relative stoichiometry and affinity of the vWF interaction with FVIII, which can be carried out on one ELISA plate.

Methods


The vWF concentration of the samples was determined using BCS® (Siemens Healthcare). Normal plasma (PNP) was obtained by pooling 15 plasma samples from healthy donors. Human vWF was used as a control (Wilate®); it was kindly donated by Octapharma. Recombinant FVIII (Recombinate®) was obtained from Baxter Deutschland GmbH. The plasma samples and controls (PNP and Wilate®) were adjusted to a vWF concentration of 10 mU/ml, by diluting them with a blocking buffer consisting of tris buffered saline (TBS) pH 8.0, supplemented with 2% bovine serum albumin (BSA). All the chemicals or reagents used were of the highest analytical grade. Each well of the high binding 96 well ELISA plates (Greiner Bio One) were coated with 150 µl of 0.05 M carbonate/bicarbonate buffer (coating buffer) pH 9.6, containing 1.5 µg/ml of capture antibody (Polyclonal Rabbit Anti-Human von Willebrand Factor, DAKO) and stored overnight at 4°C. After washing four times with TBS/BSA/Tween® washing buffer (TBS with 0.1% BSA and 0.05% Tween®20, pH 8.0) the wells were incubated for 1 h with a blocking buffer and washed again four times. Then 100 µl of TBS were added to the blanks, while 100 µl of the diluted controls and plasma samples containing 10 ng vWF were added to the other wells. After incubation periods of at least 2 h at room temperature (RT) or overnight at 4° C, the wells were washed three times with CaCl2 elution buffer (TBS with 0.1% BSA and 0.05% Tween®20, containing 350 mM of CaCl2, pH 8.0) and then incubated for 1 h at RT with CaCl2 elution buffer in order to remove all the bound FVIII from the vWF. Then the wells were washed four times with CaCl2 washing buffer (TBS with 0.1% BSA and 0.05% Tween®20, containing 10 mM of CaCl2, pH 8.0). Afterwards, blanks were incubated with CaCl2 washing buffer and the plasma probes and controls were incubated with three different concentrations 18 ng (108 mU), 6 ng (36 mU) and 2 ng (12 mU) of Recombinate® diluted in CaCl2 washing buffer for 2 h at 37°C. After washing four times with TBS/BSA/Tween® washing buffer, the blanks were incubated with TBS; the controls and plasma probes were incubated with 100 µl of a 3 µg/ml solution of polyclonal Sheep anti-human Factor VIII antibody, horseradish peroxidase (HRP) conjugated (Affinity Biologicals) in blocking buffer for 1h at RT. Then the plates were washed 9 times with TBS/BSA/Tween® washing buffer. The color was developed by adding 100 µl of H2O2 (Perhydrol®, Merck, 0.42 µl/ml) activated ortho-phenylenediamine dihydrochloride (OPD, DAKO, 0.3 mg/ml) solution. After 10 minutes of incubation at 4°C, the reaction was discontinued by adding 50µl of 2N H2SO4 per well. Then the absorbance of 492nm light was determined in a microtitre plate reader (Lambda E, BioTek) as an optical density (OD). According to the double reciprocal Lineweaver-Burk-plot [10], the relative stoichiometry and the relative affinity of the different plasma samples in relation to the PNP were determined. The gradient (a) and the point of intersection with the y-axis (b) were determined to calculate the stoichiometry of the binding sites (N = 1/b) and the affinity (K = a/b). In relation to PNP, the relative stoichiometry was calculated with N/N(PNP) and the relative affinity was calculated with K(PNP)/K.

Results


Fourteen duplicates of a normal plasma pool ranged from 0.8 to 1.3 for the relative number of the binding sites and from 0.7 to 1.5 for the relative binding affinity. The reference range (confidence interval CI 95%) as derived from 30 non-related healthy donors was 0.34 – 1.98 for the relative affinity and 0.27 – 1.47 for the relative stoichiometry. The interaction of the pure vWF derived from Wilate® with the pure FVIII (Recombinate®) was within the reference range. Even after four days of plasma storage at 4°C ±2°C, the results did not differ significantly. Two pathological samples of patients showed a markedly reduced number of binding sites concomitant with the normal affinity per binding site.

Discussion


Whenever the percentage of FVIII and the vWF differ by more than a factor of two, the relative stoichiometry and affinity can help to distinguish between the vWD 2N and other causes of the irregularity, particularly in the many cases of the more rapid degradation of FVIII, due to preanalytical influences. Even the sequencing of the vWF gene cannot reveal all of the possible mechanisms that lead to an impaired stoichiometry and affinity between the vWF and FVIII. This new method involves less material and time, when compared to the previously described home-made methods. Additionally, it offers in contrast to all other assays an easier method for achieving a detailed insight into the biological interaction between the vWF and FVIII, as was recently proposed by Favaloro [11].

Acknowledgement


We are grateful to Prof. Dr. Inge Scharrer for many helpful discussions.

References


1. Nishino M, Girma JP, Rothschild C, Fressinaud E, Meyer D. New variant of von Willebrand disease with defective binding to factor VIII. Blood 1989;74(5):1591-99.
2. López-Fernández MF, Blanco-López MJ, Castiñeira MP, Batlle J. Further evidence for recessive inheritance of von Willebrand disease with abnormal binding of von Willebrand factor to factor VIII. Am J Hematol. 1992;40(1):20-27.
3. Mazurier C, Dieval J, Jorieux S, Delobel J, Goudemand M. A new von Willebrand factor (vWF) defect in a patient with factor VIII (FVIII) deficiency but with normal levels and multimeric patterns of both plasma and platelet vWF. Characterization of abnormal vWF/FVIII interaction. Blood 1990;75(1):20-26.
4. Taylor SL, Bromidge E, Savidge GF, Alhaq A. Evaluation of an automated screening assay for von Willebrand disease type 2N. Clin Lab Haematol. 2002;24(6):369-75.
5. Casonato A, Pontara E, Zerbinati P, Zucchetto A, Girolami A. The evaluation of factor VIII binding activity of von Willebrand factor by means of an ELISA method: significance and practical implications. Am J Clin Pathol. 1998;109(3):347-52.
6. Zhukov O, Popov J, Ramos R, Vause C, Ruden S, Sferruzza A, Dlott J, Sahud M. Measurement of von Willebrand factor-FVIII binding activity in patients with suspected von Willebrand disease type 2N: application of an ELISA-based assay in a reference laboratory. Haemophilia 2009;15(3):788-96. Epub 2009 Feb 27.
7. Karlman M, Holmström M, Wilman B. A new method measuring the interaction between von Willebrand factor and coagulation factor VIII. Thromb. Res. 2011;127(1):47-50
8. Caron C, Ternisien C, Wolf M, Fressinaud E, Goudemand J, Veyradier A. An accurate and routinely adapted enzyme-linked immunosorbent assay for type2N von Willebrand disease diagnostics. Journal of Thrombosis and Haemostasis 2009; Volume 7, Supplement 2: Abstract PP-MO-626
9. Veyradier A, Caron C, Ternisien C, Wolf M, Trossaert M, Fressinaud E, Goudemand J. Validation of the first commercial ELISA for type 2N von Willebrand’s disease diagnosis. Haemophilia. 2011;Nov;17(6):944-51
10. Lineweaver H, Burk D. The Determination of Enzyme Dissociation Constants. J. Am. Chem. Soc. 1934;56 (3):658–66
11. Favaloro EJ. Interaction of factor VIII and von Willebrand factor and the identification of type 2N von Willebrand disease. Thromb. Res. 2011;127(1):2-3

Source(s) of Funding


None

Competing Interests


None

Disclaimer


This article has been downloaded from WebmedCentral. With our unique author driven post publication peer review, contents posted on this web portal do not undergo any prepublication peer or editorial review. It is completely the responsibility of the authors to ensure not only scientific and ethical standards of the manuscript but also its grammatical accuracy. Authors must ensure that they obtain all the necessary permissions before submitting any information that requires obtaining a consent or approval from a third party. Authors should also ensure not to submit any information which they do not have the copyright of or of which they have transferred the copyrights to a third party.
Contents on WebmedCentral are purely for biomedical researchers and scientists. They are not meant to cater to the needs of an individual patient. The web portal or any content(s) therein is neither designed to support, nor replace, the relationship that exists between a patient/site visitor and his/her physician. Your use of the WebmedCentral site and its contents is entirely at your own risk. We do not take any responsibility for any harm that you may suffer or inflict on a third person by following the contents of this website.

Reviews
1 review posted so far

Review of Relative Stoichiometry and Affinity for Describing Von Willebrand Factor Binding of Coagulation Factor VIII
Posted by Dr. David Nardo on 02 Nov 2017 03:23:47 AM GMT Reviewed by Interested Peers
This review will not be counted towards final review score for this article and for its inclusion into WebmedCentral Peer Reviewer articles because reviewer did not feel he/she had sufficient experience and knowledge to review the article.

Comments
0 comments posted so far

Please use this functionality to flag objectionable, inappropriate, inaccurate, and offensive content to WebmedCentral Team and the authors.

 

Author Comments
0 comments posted so far

 

What is article Popularity?

Article popularity is calculated by considering the scores: age of the article
Popularity = (P - 1) / (T + 2)^1.5
Where
P : points is the sum of individual scores, which includes article Views, Downloads, Reviews, Comments and their weightage

Scores   Weightage
Views Points X 1
Download Points X 2
Comment Points X 5
Review Points X 10
Points= sum(Views Points + Download Points + Comment Points + Review Points)
T : time since submission in hours.
P is subtracted by 1 to negate submitter's vote.
Age factor is (time since submission in hours plus two) to the power of 1.5.factor.

How Article Quality Works?

For each article Authors/Readers, Reviewers and WMC Editors can review/rate the articles. These ratings are used to determine Feedback Scores.

In most cases, article receive ratings in the range of 0 to 10. We calculate average of all the ratings and consider it as article quality.

Quality=Average(Authors/Readers Ratings + Reviewers Ratings + WMC Editor Ratings)