Webmedcentral - Surgical technique ArticlesThe Surgical technique articles published by Webmedcentral
http://www.webmedcentral.com
2024-03-28T17:28:21+01:00webmedcentral logo
http://www.webmedcentral.com/
http://www.webmedcentral.com/images/Header_Logo.giftext/html2011-06-21T18:37:21+01:00http://www.webmedcentral.com/Dr. Antonio ManentiThe \"Ultra Low\" Duodenal Stump and its Difficult Management: An Old Technique Revisited
http://www.webmedcentral.com/article_view/1998
After a subtotal gastrectomy with a concomitant resection to the whole first part of the duodenum, an “ultralow” duodenal stump is difficult to close. A safe and effective technical solution is proposed, based on the use of a Roux-en-Y jejunal loop, which permits an end-to-end duodeno-jejunal anastomosis.text/html2011-07-19T19:29:43+01:00http://www.webmedcentral.com/Dr. Antonio ManentiUnresectable Pancreatic Head Cancer: Double Palliative By-pass with a Single Roux-en.Y Jejunal Loop.
http://www.webmedcentral.com/article_view/2029
The unequivocal diagnosis of unresectability of a tumour of the head of pancreas is often challenging, and demands a careful abdominal exploration. In this case a double palliative bypass, biliary and gastro-duodenal is advisable; it can be easily constructed on the same Roux-en-Y jejunal loop, with a sequential hepatico-jejunostomy and gastro-enterostomy.text/html2011-08-22T13:39:04+01:00http://www.webmedcentral.com/Dr. Antonio ManentiBiliary reconstruction and duodenal repair with a single Roux-en-Y jejunal loop
http://www.webmedcentral.com/article_view/2107
A simple surgical technique, which permits biliary reconstruction and repair of a duodenal injury with a single Roux-en-Y jejunal loop, is described. Its simplicity and effectiveness are encouraging.text/html2011-09-22T18:49:36+01:00http://www.webmedcentral.com/Dr. Antonio ManentiFor More Definite Procedures in Colo-Rectal Oncologic Surgery.
http://www.webmedcentral.com/article_view/2231
To-day’s oncological rules suggest standardized procedures for colo-rectal neoplasms, preferring radical hemicolectomies to more limited segmental resection Usually this policy agrees with the general surgical principles.text/html2011-10-25T15:40:49+01:00http://www.webmedcentral.com/Dr. Antonio ManentiThe Left Hemicolectomy: Tecnical Reflections Towards Standard and Enlarged Procedures
http://www.webmedcentral.com/article_view/2375
The technique of left hemicolectomy (LHC) must be based on the vascular anatomy of the colon, in order to obtain an adequate lymphoadenectomy, and to assure a sufficient vascular supply to the colonic limbs, that have to be anastomosed. In particular cases this procedure can be extended to excise also the entire transverse colon, or the rectum.text/html2011-11-16T06:31:21+01:00http://www.webmedcentral.com/Dr. Antonio ManentiHighly Selective Vagotomy in the Management of Perforated Duodenal Ulcer
http://www.webmedcentral.com/article_view/2476
In the emergency treatment of a perforated duodenal ulcer (DU), after surgical closure of the perforation and treatment of the secondary peritonitis, higly selective vagotomy(HSV) is a valid therapy to prevent recurrence of the underlying disease.text/html2011-12-13T15:35:12+01:00http://www.webmedcentral.com/Dr. Antonio ManentiThe Preperitoneal Inguinal Hernia Prosthetic Repair: Indications and Technical Notes
http://www.webmedcentral.com/article_view/2622
The preperitoneal repair of an inguinal hernia (IH),performed by a classical anterior transinguinal approach is a simple and safe procedure, particularly indicated in case of evident weakness of the trasversalis fascia (TF).text/html2012-01-16T14:14:25+01:00http://www.webmedcentral.com/Dr. Antonio ManentiSynthetic Mesh Re-Styling of Pacemaker Ppockets
http://www.webmedcentral.com/article_view/2887
Different complications after Pacemaker (PM) implantation, as skin erosion, cutaneous exposure or even extrusion of the generator device, require surgical decision, with different procedures. We describe our experience, with new pocket manufacturing beneath the pectoralis major muscle (PmM) associated to wrapping of the PM generator in a polypropylene synthetic mesh. Safe anchorage and muscular plane strengthening is then achieved.